节点文献

Laser self-mixing interferometer with scalable fringe precision based on phase multiplication algorithm

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王秀琳熊彦彬徐惠真邱丽镕李震黄文财

【Author】 WANG Xiulin;XIONG Yanbin;XU Huizhen;QIU Lirong;LI Zhen;HUANG Wencai;Department of Physics, Jimei University;Department of Electronics Engineering, Xiamen University;

【通讯作者】 黄文财;

【机构】 Department of Physics, Jimei UniversityDepartment of Electronics Engineering, Xiamen University

【摘要】 In this paper, we present a phase multiplication algorithm(PMA) to obtain scalable fringe precision in laser self-mixing interferometer under a weak feedback regime. Merely by applying the double angle formula on the self-mixing signal multiple times, the continuously improved fringe precision will be obtained. Theoretical analysis shows that the precision of the fringe could be improved to λ/2n+1. The validity of the proposed method is demonstrated by means of simulated SMI signals and confirmed by experiments under different amplitudes. A fringe precision of λ/128 at a sampling rate of 500 k S/s has been achieved after doing 6 th the PMA. Finally, an amplitude of 50 nm has been proved to be measurable and the absolute error is 3.07 nm, which is within the theoretical error range. The proposed method for vibration measurement has the advantage of high accuracy and reliable without adding any additional optical elements in the optical path, thus it will play an important role in nanoscale measurement field.

【Abstract】 In this paper, we present a phase multiplication algorithm(PMA) to obtain scalable fringe precision in laser self-mixing interferometer under a weak feedback regime. Merely by applying the double angle formula on the self-mixing signal multiple times, the continuously improved fringe precision will be obtained. Theoretical analysis shows that the precision of the fringe could be improved to λ/2n+1. The validity of the proposed method is demonstrated by means of simulated SMI signals and confirmed by experiments under different amplitudes. A fringe precision of λ/128 at a sampling rate of 500 k S/s has been achieved after doing 6 th the PMA. Finally, an amplitude of 50 nm has been proved to be measurable and the absolute error is 3.07 nm, which is within the theoretical error range. The proposed method for vibration measurement has the advantage of high accuracy and reliable without adding any additional optical elements in the optical path, thus it will play an important role in nanoscale measurement field.

【关键词】 fringeinterferometermultiplicationmixingabsolutescalableapplyingaddingvaliditydoing
【基金】 supported by the Natural Science Foundation of Fujian Province (No.2020J01705);the School Foundation of Jimei University (No.C150345)
  • 【文献出处】 Optoelectronics Letters ,光电子快报(英文版) , 编辑部邮箱 ,2021年11期
  • 【分类号】TH744.3
  • 【下载频次】27
节点文献中: 

本文链接的文献网络图示:

本文的引文网络