【机构】 中国农业科学院特产研究所

【摘要】 试验采用超高效液相色谱法(UPLC)对浓缩饲料中维生素K3的含量进行测试,并评估此试验的测量不确定度。浓缩饲料中的维生素K3类饲料添加剂经三氯甲烷和碳酸钠溶液提取,转化为游离的甲萘醌,经C18反相色谱柱分离,PDA检测器在251nm波长处检测,外标法定量即得浓缩饲料中维生素K3的含量。经检测浓缩饲料中维生素K3的含量为:(1.42±0.07)mg·kg-1,k=2(95%置信度)。测量不确定度的评定结果表明,标准储备液和标准工作液配制过程是影响测量结果的主要因素。

【Abstract】 Vitamin K3 was extracted by chloroform and sodium carbonate solution and then transformed into free menadione.It was separated by C18 reversed-phase chromatographic column.The vitamin K3 was determined by PDA detector at the wavelength of 251 nm,and quantified by external standard method.The test results showed that the content of vitamin K3 was(1.42±0.07)mg·kg-1,k=2(95%confidence).The evaluation results showed that the main influence factors were the preparation process of standard stock solution and working solution.