基于PARTER开展肿瘤Flash-RT研究——设计及计算

Design and calculation of Flash-RT based on PARTER

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 高峰曹璐璐羊奕伟杜小波戴堂知吴岱

【Author】 GAO Feng;CAO Lulu;YANG Yiwei;DU Xiaobo;DAI Tangzhi;WU Dai;Mianyang Central Hospital;North Sichuan Medical College;Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics;Institute of Applied Electronics, China Academy of Engineering Physics;

【通讯作者】 羊奕伟;

【机构】 绵阳市中心医院川北医学院中国工程物理研究院核物理与化学研究所中国工程物理研究院应用电子研究所

【摘要】 闪光放疗(Flash-RT)是近年来国际肿瘤放疗研究的前沿科技和研究热点,其使用超大剂量率(通常大于100 Gy/s)在极短时间(1~50 ms)内将全部放疗剂量注入靶区。研究发现其对正常组织体现出更小的损伤,同时可呈量级地降低放疗时间。中国工程物理研究院太赫兹自由电子激光装置上的超导电子加速器可提供最高平均流强5 mA的6~8 MeV电子束流,基于它的先进放疗研究平台(PARTER)具有Flash-RT研究的潜力。本文首次介绍PARTER及详细的Flash-RT专用靶和准直器物理设计方案,并给出关键参数的蒙特卡罗模拟计算结果。根据设计,平台上生物样品内注入的最高剂量率达2 000 Gy/s,剂量注入时间从μs到百ms持续可调,100 Gy/s以上剂量率覆盖深度超过20 cm,符合Flash-RT研究要求。文中给出了详细的计算过程和结果分析,以提供给之后在PARTER上开展Flash-RT实验研究作为基本参考数据。

【Abstract】 Flash radiotherapy(Flash-RT) which is an international cutting-edge technology and hotspot in the domain of tumor radiotherapy in recent years delivers all the treatment dose into the target area in an ultra-short time(about 1-50 ms)at ultra-high dose rate(usually >100 Gy/s). Various researches revealed that Flash-RT could significantly reduce the time of radiotherapy and bring less damage to normal tissues. The superconducting electron accelerator of the CTFEL facility in China Academy of Engineering Physics can produce 6-8 MeV electron beam up to 5 mA in average current, and the platform for advanced radiotherapy research(PARTER) based on the superconducting electron accelerator should be a suitable platform for Flash-RT research. Herein PARTER and the detailed design schemes of Flash-RT specific targets and collimators are firstly introduced. According to Monte Carlo simulation, the maximum dose rate for the biological samples on the platform was up to 2 000 Gy/s, and the exposure time was continuously adjustable from μs to 100 ms, and the coverage depth for dose rate larger than 100 Gy/s was more than 20 cm, which meet the requirements of Flash-RT research.The detailed calculation process and result analysis are described for providing some basic reference data for the following Flash-RT experiments which are carried out on PARTER.

【基金】 国家自然科学基金(11790321,11675155);中国工程物理研究院院长基金(YZLX2017003)
  • 【文献出处】 中国医学物理学杂志 ,Chinese Journal of Medical Physics , 编辑部邮箱 ,2020年09期
  • 【分类号】R730.55
  • 【被引频次】1
  • 【下载频次】166
节点文献中: 

本文链接的文献网络图示:

本文的引文网络