【作者】 蒋悦花春文

【Author】 Jiang Yue;Hua Chunwen;School of Materials and Environmental Protection,Chengdu Textile College;Sichuan Zhongce Environmental Technology Co.,Ltd.;

【机构】 成都纺织高等专科学校材料与环保学院四川中测环境技术有限公司

【摘要】 通过对某城市污水厂反硝化深床滤池的运行研究,分析了m (C)/m (N)值、滤池HRT及DO等对脱氮效果的影响。结果表明m (C)/m (N)值大于5时,会影响脱氮效果,导致COD去除率降低,HRT为30min时,最适合该处理工艺的脱氮,并且建议采取措施减少跌水复氧,确保脱氮效果,减少复氧消耗的外加碳源。

【Abstract】 The analysis process about effects of C/N,HRT and DO in filter on nitrogen removal were carried out in a municipal WWTP.The study shows that the removal efficiency of nitrogen and COD will be lower,when C/N > 5 and the HRT =30 min is most suitable.It is suggested that reducing reoxygenation to ensure the effect of nitrogen removal,meanwhile reduce the consumption of additional carbon sources.