节点文献
快速水蒸气蒸馏-流动注射分析仪联用测定食品中氰化物
Determination of Cyanide in Food by Rapid Steam Distillation-Flow Injection Analysis
【摘要】 建立快速水蒸气蒸馏仪提取食品样品中的氰化物,流动注射分析仪测定馏出液中氰化物含量的方法。结果表明:在0~0.500μg/mL质量浓度范围内,方法标准曲线线性良好,相关系数为0.999 6,当取样量为20 g,定容体积为250 mL时,方法检出限为0.014 mg/kg。利用该方法和国标方法同时对实际样品进行检测,所得结果相对偏差均小于10%。该方法重复性好,回收率稳定,能够满足实际检测的要求。
【Abstract】 A method for determining cyanide in food using rapid steam distillation combined with flow injection analyzer was established. The results showed that within the mass concentration range of 0-0.500 μg/mL,the standard curve of the method had good linearity,and the correlation coefficient was 0.999 6. When the sample amount was 20 g and the volume was 250 mL,the detection limit of the method was 0.014 mg/kg. The method and the national standard method were used to simultaneously detect the actual samples,and the relative deviation of the results was less than 10 %. The repetitive determination of the actual samples showed that the precision and recovery of the standard addition were in good order to meet the actual detection requirements.
【Key words】 flow injection analysis; cyanide; food; steam distillation;
- 【文献出处】 食品研究与开发 ,Food Research and Development , 编辑部邮箱 ,2020年19期
- 【分类号】TS207.3
- 【被引频次】5