节点文献

Sub-millikelvin station at Synergetic Extreme Condition User Facility

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 程智刚樊洁景秀年吕力

【Author】 Zhi Gang Cheng;Jie Fan;Xiunian Jing;Li Lü;Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences;School of Physical Sciences, University of Chinese Academy of Sciences;

【机构】 Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of SciencesSchool of Physical Sciences, University of Chinese Academy of Sciences

【摘要】 The Institute of Physics, Chinese Academy of Sciences, is in charge of the construction of the Synergetic Extreme Condition User Facility(SECUF) in Huairou, Beijing. The SECUF is a comprehensive facility focused on providing extreme physical conditions for scientific research, including an ultralow temperature, ultrahigh pressure, ultrahigh magnetic field, and ultrafast laser. The ultralow temperature will be realized by the sub-millikelvin(sub-mK) station, whose main component is an adiabatic nuclear demagnetization refrigerator(ANDR). The refrigerator is designed to have a base temperature below 1 mK and a magnetic field up to 16 T for experiments, as well as a characteristic parameter of B/T≥10~4 T/K.In this review, we introduce adiabatic nuclear demagnetization refrigeration, thermometry from 10 mK to sub-mK, the properties and parameters of the ANDR of the SECUF, and related prospective research topics.

【Abstract】 The Institute of Physics, Chinese Academy of Sciences, is in charge of the construction of the Synergetic Extreme Condition User Facility(SECUF) in Huairou, Beijing. The SECUF is a comprehensive facility focused on providing extreme physical conditions for scientific research, including an ultralow temperature, ultrahigh pressure, ultrahigh magnetic field, and ultrafast laser. The ultralow temperature will be realized by the sub-millikelvin(sub-mK) station, whose main component is an adiabatic nuclear demagnetization refrigerator(ANDR). The refrigerator is designed to have a base temperature below 1 mK and a magnetic field up to 16 T for experiments, as well as a characteristic parameter of B/T≥10~4 T/K.In this review, we introduce adiabatic nuclear demagnetization refrigeration, thermometry from 10 mK to sub-mK, the properties and parameters of the ANDR of the SECUF, and related prospective research topics.

【基金】 Project supported by the National Basic Research Program of China(Grant Nos.2016YFA0300601,2015CB921402,2011CB921702,and 2009CB929101);the National Natural Science Foundation of China(Grant Nos.11527806,91221203,11174340,11174357,and 91421303);the Strategic Priority Research Program B of the Chinese Academy of Sciences(Grant No.XDB07010100);the support from Hundreds Talent Program,Chinese Academy of Sciences
  • 【文献出处】 Chinese Physics B ,中国物理B , 编辑部邮箱 ,2018年07期
  • 【分类号】O51
  • 【下载频次】15
节点文献中: 

本文链接的文献网络图示:

本文的引文网络