节点文献

基于双谐振声波幅相控制的高声强级校准

Calibration of High Sound Intensity Lever Based on Amplitude-Phase Control for Dual Resonance Sound Waves

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨晓伟闫磊朱刚刘鑫白天

【Author】 YANG Xiao-wei;YAN lei;ZHU Gang;LIU Xin;BAI Tian;Beijing Aerospace Institute for Metrology and Measurement and Technology;

【机构】 北京航天计量测试技术研究所

【摘要】 对声强测量仪高声强级校准方法的发展历程、现状及水平进行论述,采用两个声压级高、失真度低的声源研发了高声强级校准系统,提出了双谐振声波幅相控制的新方法使声强级校准在频率500Hz时上限可达150dB以上,而失真度小于0.5%。给出高声强校准系统的校准实例和不确定度评估。

【Abstract】 The calibration methods of high intensity lever for sound intensity probe,its present and history are described.Based on the two sound sources with high-pressure level and low distortion,the high sound intensity lever calibration system has been developed.A new method named amplitude-phase control for dual resonant sound waves is proposed,and new calibration system can generate high sound intensity levels up to 150 dB at 500 Hz with distortion(<0.5%).The calibration example and uncertainty evaluation of the new system are also given.

  • 【文献出处】 宇航计测技术 ,Journal of Astronautic Metrology and Measurement , 编辑部邮箱 ,2018年06期
  • 【分类号】V416.8;TB52
  • 【被引频次】2
  • 【下载频次】42