节点文献

室内步行街玻喷系统响应时间影响因素研究

Research on the influence factors of response time of glass water spray system in indoor pedestrian street

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 韩如适张向阳

【Author】 HAN Ru-shi;ZHANG Xiang-yang;Institute of Building Fire Research, China Academy of Building Research;

【机构】 中国建筑科学研究院建筑防火研究所

【摘要】 为提高室内步行街"玻璃+水喷淋"系统的效能,调研室内步行街玻喷系统现状,得到影响玻喷系统响应时间的因素。针对3种典型吊顶形式,分别设定房间内喷头与玻喷喷头水平距离0.4~3.2 m、火源距玻喷喷头水平距离0~4.0 m的场景,采用大涡模拟定量分析影响玻喷系统响应时间的因素,讨论喷头间距、火源位置对玻喷系统响应时间的影响。提出步行街商铺玻喷系统的设计与安装建议,为室内步行街商铺临街处的防火分隔设计提供参考。

【Abstract】 In order to enhance the efficiency of "glass + water spray"in indoor pedestrian street, the status of glass water spray system in indoor pedestrian street was investigated and the influence factors on response time of glass water spray system were obtained. According to 3 kinds of typical suspended ceiling, scenarios that the distance from room nozzle to glass nozzle is 0.4~3.2 m,and horizontal distance from fire to glass nozzle is 0~4.0 m were set to analyze the factors quantitatively which influence the response time of glass water spray system by large eddy simulation.The influence of distance between nozzles and fire location on the response time of glass water spray system was researched. Suggestions on the design and construction of glass water spray system in indoor pedestrian street were put forward to give reference for fire separation design of street side of shops in indoor pedestrian street.

【基金】 中国建筑科学研究院青年科研基金项目“室内步行街火灾蔓延控制关键技术研究”(20160111331030069)
  • 【文献出处】 消防科学与技术 ,Fire Science and Technology , 编辑部邮箱 ,2018年03期