A test device for determining the scaling critical point of reverse osmosis inlet water is proposed based on turbidimetric method. By using this device, the scaling risk of circulating sewage treated and reused by reverse osmosis in a power plant is evaluated. The performance of five domestically produced reverse osmosis scale inhibitors developed by another power plant project is evaluated. The results show that, the turbidimetric method can quickly and accurately determine scaling critical point and scali...
【更新日期】
2018-09-06
【分类号】
TQ085;X773
【正文快照】
A distinguishing method of scaling critical point of reverse osmosis inlet waterand its applicationZHANG Longming1,YANG Chunyan2,ZHAO Xiaolin3,TIAN Li1,DAI Xin1,SHEN Xiaoxiang1(1.Xi’an Thermal Power Research Institute Co.,Ltd.,Xi’an 710054,China;2.Guang