节点文献
俄制800 MW超临界锅炉顶棚水冷壁管泄漏原因分析
Analysis of Leakage Causes of Roof Water-Cooling Wall in 800 MW Supercritical Boiler Made in Russia
【摘要】 分析了国华神华绥中发电有限公司1号和2号超临界锅炉顶棚水冷壁泄漏的主要原因,结合锅炉实际情况,提出了相应的改造方案,为锅炉顶棚水冷壁的改造提供依据。
【Abstract】 This paper analyzes the main causes of the roof water-cooling wall leakage in No. 1 and No. 2 supercritical boilers in Guohua Shenhua Suizhong Power Generation Co.,Ltd.,Combining the actual operating conditions of the boilers,it puts forward a reform project which provides a foundation for the reform of the roof water-cooling wall.
【关键词】 超临界锅炉;
顶棚水冷壁;
泄漏;
治理;
【Key words】 supercritical boiler; roof water-cooling wall; leakage; governance;
【Key words】 supercritical boiler; roof water-cooling wall; leakage; governance;
- 【文献出处】 东北电力技术 ,Northeast Electric Power Technology , 编辑部邮箱 ,2018年11期
- 【分类号】TM621.2