节点文献

A335P11钢在流动加速腐蚀条件下的管壁减薄行为

Pipeline Wall Thinning Behavior of A335P11 Steel under the Condition of Flow Accelerated Corrosion

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王亮亮饶德林匡波张贤刘军良陈宝

【Author】 WANG Liangliang;RAO Delin;KUANG Bo;ZHANG Xian;LIU Junliang;CHEN Bao;School of Nuclear Science and Engineering,Shanghai Jiao Tong University;State Nuclear Electric Power Plant Design & Research Institute;

【通讯作者】 王亮亮;

【机构】 上海交通大学核科学与工程学院国核电力规划设计研究院

【摘要】 模拟了核电厂常规岛二回路工况,研究了此工况条件下A335P11钢弯管测试段、变径测试段及三通测试段的腐蚀减薄现象。结果表明:发生流动加速腐蚀(FAC)最严重的部位是弯管内弧面、变径管的渐缩管段出口处以及三通测试段的辅出水口处。

【Abstract】 The conditions of the second loop of the conventional island in nuclear power plant were simulated,and the corrosion thinning behavior of A335 P11 pipeline in elbow test section,variable diameter test section and three-way test section under this working condition was studied.The results showed that the most serious site of FAC occured at the inner arc surface of the elbow,the outlet of tapered pipe section of the adjustable pipe,and the auxiliary outlet of the three-way test section.

  • 【文献出处】 腐蚀与防护 ,Corrosion & Protection , 编辑部邮箱 ,2018年07期
  • 【分类号】TM623
  • 【被引频次】6
  • 【下载频次】166
节点文献中: 

本文链接的文献网络图示:

本文的引文网络