节点文献

风电变流器改进型断续脉宽调制策略

Improved Discontinuous Pulse Width Modulation Strategy for Wind Power Converters

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 耿毓廷李姗李武华何湘宁曹丰文

【Author】 GENG Yuting;LI Shan;LI Wuhua;HE Xiangning;CAO Fengwen;College of Electrical Engineering,Zhejiang University;No.704 Research Institute,China Shipbuilding Industry Corporation;School of Electronics and Information Engineering,Suzhou Vocational University;

【机构】 浙江大学电气工程学院中国船舶重工集团公司第七〇四研究所苏州市职业大学电子信息工程学院

【摘要】 大功率风力发电变流器中,存在开关损耗和电流总谐波失真THD(total harmonic distortion)难以均衡的矛盾。如何优化调制方式,以提高系统效率,减小电流谐波,是大功率风电变流系统的核心技术之一。针对风电变流器宽频率、宽电压运行范围的特点,分析直驱风电变流器采用断续脉宽调制策略下的损耗和谐波性能,发现不同工况下主要关注指标不同,轻载时电能质量恶劣、开关损耗低,而重载时开关损耗严重、电能质量好;但是常用调制方式很难兼顾。为解决该问题,提出一种适用于永磁同步机直驱风电变流器的新型断续脉宽调制策略,该调制策略对开关损耗和THD的优化特性随变流器工作范围变化,实现不同工况下主要关注指标的优化。最后通过实验平台验证了该方案在重载时减小开关损耗,在轻载时降低电流谐波的有效性。

【Abstract】 For a high-power wind power converter, there is a contradiction between switching loss and the total harmonic distortion(THD) of current. How to optimize its modulation mode and thus improve the system efficiency and reduce the current harmonics is one of the core technologies of high-power wind power converter system. Considering the characteristics of wind power converters’ wide operating ranges of frequency and voltage, the loss and harmonic performance of direct-drive wind power converters under discontinuous pulse width modulation(DPWM) strategy is studied. It is found that the main indicators are different under different operating conditions:at light loads,the power quality is poor and the switching losses are small; at heavy loads,the power quality is good and the switching losses are large. However, common modulation methods are difficult to strike a balance between THD and switching losses. To solve this problem, a novel DPWM strategy is proposed for the direct-drive wind power converters of permanent magnet synchronous machines.Under this modulation strategy, the switching losses and optimal characteristics of THD vary with the operating range of the converter,which realizes the optimization of main indicators under different operating conditions. Finally, through an experimental platform, it was verified that the proposed scheme was effective to reduce the switching loss at heavy loads and reduce the current harmonics at light loads.

【基金】 国家自然科学基金资助项目(51377112)~~
  • 【文献出处】 电源学报 ,Journal of Power Supply , 编辑部邮箱 ,2018年02期
  • 【分类号】TM46
  • 【被引频次】4
  • 【下载频次】181
节点文献中: 

本文链接的文献网络图示:

本文的引文网络