For a moving-magnet double stators linear compressor,the equivalent magnetic circuit model was established to calculate the air gap flux,electromagnetic force,electromagnetic force coefficient,back EMF coefficient and inductance of motor on the basis of analyzing the motor operation principle. Then,finite element analysis for the motor was implemented to verify the analytical results. According to the calculation results of the control parameters,the dynamic characteristics of the linear compressor system w...