节点文献
隔爆型电动机的参考压力测定与静压试验
Determination of Reference Pressure and Static Pressure Test of Flameproof Motor
【摘要】 论述了隔爆型电动机的参考压力测定与静压试验之间的关系,从试验数据说明电机由于压力重叠现象导致产生较大的爆炸压力,应按1.5倍的参考压力来进行静压试验,从而保障电机的防爆性能。
【Abstract】 It illustrates the relationship between determination of reference pressure and static pressure test,gives a conclusion that bigger pressure may raised due to pressure pilling,suggests that 1.5 times the reference pressure shall be used during static pressure test to ensure the explosion-proof performance.
【关键词】 防爆电机;
隔爆;
参考压力;
静压试验;
【Key words】 explosion-proof motor; flameproof; reference pressure; static pressure test;
【Key words】 explosion-proof motor; flameproof; reference pressure; static pressure test;
- 【文献出处】 电气防爆 ,Electric Explosion Protection , 编辑部邮箱 ,2018年01期
- 【分类号】TM357
- 【被引频次】3
- 【下载频次】75