LC-MS/MS法和EMIT法测定人血清中丙戊酸浓度的对比研究
Comparative Stndy on Concentration Determination of Valproic Acid in Human Serum by LC-MS/MS and EMIT
【摘要】 目的:比较液相色谱-串联质谱(LC-MS/MS)法与酶放大免疫(EMIT)法测定人血清中丙戊酸(VPA)浓度的差异,为临床治疗药物监测提供参考。方法:分别采用LC-MS/MS法和EMIT法对144份住院或门诊患者血清样品中的VPA浓度进行检测,采用配对t检验、Pearson相关性分析和Bland-Altman偏差图等方法对其检测结果的差异进行评价。结果:LC-MS/MS法和EMIT法的检测结果呈正相关(r=0.924,P<0.05);两者的回归方程为cEMIT=0.920 7cLC-MS/MS-1.114 4(r=0.924);LC-MS/MS法和EMIT法测得的VPA平均血药浓度分别为(49.9±21.2)、(54.9±21.3)μg/m L,组间比较差异有统计学意义(P<0.05);EMIT法检测结果比LC-MS/MS法偏高8.3μg/mL,95%置信区间为(-13.6,18.7)。结论:LC-MS/MS法和EMIT法测定人血清中VPA的浓度相关性良好,但检测结果有一定的差异,建议同一患者长期监测应选用同一种方法。
【Abstract】 OBJECTIVE:To compare the difference in the concentration determination of valproic acid(VPA)in human serum by LC-MS/MS and EMIT. METHODS:Both LC-MS/MS and EMIT methods were applied to determine the serum concentration of VPA in 144 inpatients or outpatients. The paired t-test,Pearson correlation analysis,Bland-Altman deviation chart and other methods were used to evaluate the difference in the results of concentration determination. RESULTS:The results of LC-MS/MS method was positively correlated with that of EMIT method(r=0.924,P<0.05);the regression equation of them was cEMIT=0.920 7cLC-MS/MS-1.114 4(r=0.924). Average serum concentrations of VPA determined by LC-MS/MS and EMIT were(49.9±21.2)and(54.9±21.3)μg/m L,with statistical significance(P<0.05). The serum concentration of VPA determined by EMIT was higher than that by LC-MS/MS8.3 μg/m L,95% confidence interval was(-13.6,18.7). CONCLUSIONS:The serum concentration of VPA determined by LC-MS/MS and EMIT have high correlation. But the determination results still have certain difference,it is suggested to use same method for longterm monitering.
【Key words】 Valproic acid; Serum concentration; LC-MS/MS; EMIT; Difference;
- 【文献出处】 中国药房 ,China Pharmacy , 编辑部邮箱 ,2017年08期
- 【分类号】R969.1;O657.63
- 【被引频次】6
- 【下载频次】243