节点文献

Investigation of the nonlinear CPT spectrum of 87Rb and its application for large dynamic magnetic measurement

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 徐迟王时光胡勇冯焱颖王力军

【Author】 Chi Xu;Shi-Guang Wang;Yong Hu;Yan-Ying Feng;Li-Jun Wang;Department of Physics,Tsinghua University;Joint Institute for Measurement Science,Tsinghua University;State Key Laboratory of Precision Measurement Technology and Instrument,Tsinghua University;

【机构】 Department of Physics,Tsinghua UniversityJoint Institute for Measurement Science,Tsinghua UniversityState Key Laboratory of Precision Measurement Technology and Instrument,Tsinghua University

【摘要】 The coherent population trapping(CPT) phenomenon has found widespread application in quantum precision measurements. Various designs based on the narrow resonant spectrum corresponding to the linear Zeeman effect have been demonstrated to achieve high performance. In this article, the nonlinear Zeeman split of the CPT spectrum of 87Rb in the lin||lin setup is investigated. We observe re-split phenomenon for both magnetic sensitive and magnetic insensitive CPT resonant lines at a large magnetic field. The re-split in the magnetic sensitive lines raises a practical problem to magnetometers worked in the lin||lin setup while the other one shows a good potential for applications in large magnetic field. We propose a design based on the nonlinear split of the magnetic insensitive lines and test its performance. It provides a much larger measurement range compared to the linear one, offering an option for atomic magnetometers where a large dynamic range is preferred.

【Abstract】 The coherent population trapping(CPT) phenomenon has found widespread application in quantum precision measurements. Various designs based on the narrow resonant spectrum corresponding to the linear Zeeman effect have been demonstrated to achieve high performance. In this article, the nonlinear Zeeman split of the CPT spectrum of 87Rb in the lin||lin setup is investigated. We observe re-split phenomenon for both magnetic sensitive and magnetic insensitive CPT resonant lines at a large magnetic field. The re-split in the magnetic sensitive lines raises a practical problem to magnetometers worked in the lin||lin setup while the other one shows a good potential for applications in large magnetic field. We propose a design based on the nonlinear split of the magnetic insensitive lines and test its performance. It provides a much larger measurement range compared to the linear one, offering an option for atomic magnetometers where a large dynamic range is preferred.

【基金】 supported by the National Natural Science Foundation of China(Grant No.61473166);China Postdoctoral Science Foundation(Grant No.014M560958)
  • 【文献出处】 Chinese Physics B ,中国物理B , 编辑部邮箱 ,2017年06期
  • 【分类号】O562
  • 【被引频次】2
  • 【下载频次】31
节点文献中: 

本文链接的文献网络图示:

本文的引文网络