Since RS- 485 communication port plays a minor role in operation of electric energy meter,the original requirements and functions requested for each communication port of the meter is retrieved,the features of communication port,especially the infrared communication are researched,and the feasibility of using infrared communication port to implement all the functions of RS- 485 ports is investigated. Infrared port is space open port,multiple pairs of infrared communication ports may interfere to each other ...