节点文献

Fast Electrical Detection of Carcinoembryonic Antigen Based on AlGaN/GaN High Electron Mobility Transistor Aptasensor

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 占香蜜王权王琨李巍肖红领冯春姜丽娟王翠梅王晓亮王占国

【Author】 Xiang-Mi Zhan;Quan Wang;Kun Wang;Wei Li;Hong-Ling Xiao;Chun Feng;Li-Juan Jiang;Cui-Mei Wang;Xiao-Liang Wang;Zhan-Guo Wang;Key Lab of Semiconductor Materials Science,Institute of Semiconductors,Chinese Academy of Sciences;School of Microelectronics,University of Chinese Academy of Sciences;Beijing Key Laboratory of Low Dimensional Semiconductor Materials and Devices;

【机构】 Key Lab of Semiconductor Materials Science,Institute of Semiconductors,Chinese Academy of SciencesSchool of Microelectronics,University of Chinese Academy of SciencesBeijing Key Laboratory of Low Dimensional Semiconductor Materials and Devices

【摘要】 As one of the most important tumor-associated antigens of colorectal adenocarcinoma, the carcinoembryonic antigen(CEA) threatens human health seriously all over the globe. Fast electrical and highly sensitive detection of the CEA with AlGaN/GaN high electron mobility transistor is demonstrated experimentally. To achieve a low detection limit, the Au-gated sensing area of the sensor is functionalized with a CEA aptamer instead of the corresponding antibody. The proposed aptasensor has successfully detected different concentrations(ranging from 50 picogram/milliliter(pg/ml) to 50 nanogram/milliliter(ng/ml)) of CEA and achieved a detection limit as low as 50 pg/ml at Vds = 0.5 V. The drain-source current shows a clear increase of 11.5μA under this bias.

【Abstract】 As one of the most important tumor-associated antigens of colorectal adenocarcinoma, the carcinoembryonic antigen(CEA) threatens human health seriously all over the globe. Fast electrical and highly sensitive detection of the CEA with AlGaN/GaN high electron mobility transistor is demonstrated experimentally. To achieve a low detection limit, the Au-gated sensing area of the sensor is functionalized with a CEA aptamer instead of the corresponding antibody. The proposed aptasensor has successfully detected different concentrations(ranging from 50 picogram/milliliter(pg/ml) to 50 nanogram/milliliter(ng/ml)) of CEA and achieved a detection limit as low as 50 pg/ml at Vds = 0.5 V. The drain-source current shows a clear increase of 11.5μA under this bias.

【关键词】 AlGaNcolorectaldrainseriouslyElectrongatedtransistorinsteadAntigenadenocarcinoma
【基金】 Supported by the National Key Research and Development Program of China under Grant Nos 2016YFB0400104 and 2016YFB0400301;the National Natural Science Foundation of China under Grant No 61334002;the National Science and Technology Major Project
  • 【文献出处】 Chinese Physics Letters ,中国物理快报(英文版) , 编辑部邮箱 ,2017年09期
  • 【分类号】R730.4;TN386
  • 【被引频次】2
  • 【下载频次】25
节点文献中: 

本文链接的文献网络图示:

本文的引文网络