带面罩的呼气控制装置治疗慢性阻塞性肺疾病的临床观察

Clinical observation of treatment used for expiration control device with mask for chronic obstructive pulmonary disease

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘斌秦建文李文全

【Author】 LIU Bin;QIN Jianwen;LI Wenquan;Department of Respiratory and Critical Care,Tianjin Chest Hospital;

【机构】 天津市胸科医院呼吸与危重症科

【摘要】 目的检验笔者自行研制的带面罩的呼气控制装置治疗慢性阻塞性肺疾病(COPD)的疗效。方法接受带面罩的呼气控制装置治疗的102例患者中50例患者使用该装置的呼气末正压功能治疗,另外52例患者使用该装置的呼气延阻功能治疗,观察治疗前后患者动脉血气分析中二氧化碳分压(PaCO2)、氧分压(PaO2)、pH值及肺功能中用力肺活量(FVC)、一秒量(FEV1)、潮气量(VT)差异。结果(1)呼气末正压治疗组治疗前后肺功能FVC、FEV1、VT(2.95±0.32)L vs(3.22±0.35)L,(1.88±0.17)L vs(2.00±0.15)L,(335.28±43.59)mL vs(364.64±44.28)mL(均P<0.01)差异有统计学意义;动脉血PaCO2,PaO2,pH(50.42±4.77)mmHg vs(48.42±3.76)mmHg,(65.42±4.60)mmHg vs(68.50±4.69)mmHg,(7.35±0.030)vs(7.37±0.037)(均P<0.05)差异有统计学意义;(2)呼气延阻治疗组治疗前后肺功能FVC、FEV1、VT(2.93±0.22)L vs(3.10±0.27)L,(1.83±0.14)L vs(1.91±0.16)L,(335.48±44.16)mL vs(362.46±38.66)mL(均P<0.05)差异有统计学意义;动脉血PaCO2,PaO2,pH(52.39±3.37)mmHg vs(50.06±3.92)mmHg,(68.05±3.80)mmHg vs(68.99±4.57)mmHg,(7.34±0.035)vs(7.37±0.036)(均P<0.05)差异有统计学意义。结论带面罩的呼气控制装置能够改善COPD患者通气功能,使用方便、安全有效,具有较高的临床应用价值。

【Abstract】 Objective To test the clinical effects of the expiration control device with mask in the treatment of chronic obstructive pulmonary disease.This device developed by the author.Method s A total of 102 patients were treated by the device.Among them,50 patients received positive end-expiratory pressure and 52 with expiratory flow retard and blocked function.Differences in carbon dioxide partial pressure(PaCO2),oxygen partial pressure(PaO2)and pH of the arterial blood gas analysis were compared,as well as differences in forced vital capacity(FVC),forced expiratory volume for1 sec(FEV1),tidal volume(VT)of pulmonary function before and after treatment.Results (1)In the positive end-expiratory pressure group,there were significant differences of FVC,FEV1 and VT before and after treatment(2.95±0.32)L vs(3.22±0.35)L,(1.88±0.17)L vs(2.00±0.15)L,(335.28±43.59)mL vs(364.64±44.28)mL,(P<0.01)differences of PaCO2,PaO2and pH before and after treatment had statistical significance(50.42±4.77)mmHg vs(48.42±3.76)mmHg,(65.42±4.60)mmHg vs(68.50±4.69)mmHg,(7.35±0.030)vs(7.37±0.037)(P<0.05)(.2)In the expiratory flow retard and blocked group,differences of FVC,FEV1and VT before and after treatment had statistical significance(2.93±0.22)L vs(3.10±0.27)L,(1.83±0.14)L vs(1.91±0.16)L,(335.48±44.16)mL vs(362.46±38.66)mL(P<0.05),differences of PaCO2,PaO2and pH before and after treatment had statistical significance(52.39±3.37)mmHg vs(50.06±3.92)mmHg,(68.05±3.80)mmHg vs(68.99±4.57)mmHg,(7.34±0.035)vs(7.37±0.036)(P<0.05).Conclusion This device can improve the ventilation function in patients with COPD.It is easy to use,safe and effective,with high clinical application value.

  • 【文献出处】 实用医学杂志 ,The Journal of Practical Medicine , 编辑部邮箱 ,2017年13期
  • 【分类号】R563.9
  • 【网络出版时间】2017-08-09 21:04:04
  • 【被引频次】1
  • 【下载频次】31
节点文献中: 

本文链接的文献网络图示:

本文的引文网络