节点文献
阿哌沙班中8种已知杂质的HPLC法定量检测
Quantitative determination of eight known kinds of impurities in Apixaban by HPLC
【摘要】 建立高效液相色谱法测定阿哌沙班中的8个已知杂质。色谱柱为Waters Xbridge Shield RP18(150mm×4.6mm,5μm);以乙腈-醋酸铵溶液为流动相,柱温:40℃,流量:1.0 m L/min,检测波长280 nm。阿哌沙班中8种杂质分离较好,与主峰均能有效分离,线性范围为0.01~11μg/m L;8种杂质的平均回收率分别为98.7%,105.3%,100.7%,111.4%,97.4%,103.4%,98.9%,97.6%,RSD分别为2.8%,4.3%,3.3%,4.5%,3.1%,4.0%,2.7%,3.1%。该法简便、准确、重复性好,可为阿哌沙班质量标准的制定提供参考。
【Abstract】 To establish an HPLC method to determine eight kinds of impurities in Apixaban.Chromatographic column is Waters Xbridge Shield RP18(150 mm ×4.6 mm,5 μm),acetonitrile-ammonium acetate solution is mobile phase,The column temperature is 40 ℃ and the flow velocity is 1.0 m L/min,The detection wavelength is 280 nm.Eight kinds of impurities in Apixaban were separated from the primary front effectively and the linearity range was 0.01-11 μg/m L.The average recovery rates of the eight impurities are 98.7%,105.3%,100.7%,111.4%,97.4%,103.4%,98.9%,97.6%,and the RSDs were 2.8%,4.3%,3.3%,4.5%,3.1%,4.0%,2.7%,3.1%.This method is simple,accurate and of good repeatability.It provides quality standards for erythromycin apixaban.
【Key words】 Apixaban; high performance liquid chromatographic method; impurities; recovery rate; separate;
- 【文献出处】 中国测试 ,China Measurement & Test , 编辑部邮箱 ,2017年03期
- 【分类号】O657.72;TQ460.72
- 【被引频次】4
- 【下载频次】238