【Author】 TAO Ran;LI Bo;NI Lu-guang;ZHENG Zhi-shan;YANG Jin-quan;GAO Hong;LI Na;HE Jun;HU Zhao-hui;Laboratory Management Center,Guangzhou Kingmed Center for Clinical Laboratory;Laboratory Diagnosis Department,Jilin Kingmed Center for Clinical Laboratory;Laboratory Diagnosis Department,Shijiazhuang Kingmed Center for Clinical Laboratory;Laboratory Diagnosis Department,Wuhan Kingmed Center for Clinical Laboratory;Laboratory Diagnosis Department,Jinan Kingmed Center for Clinical Laboratory;

【机构】 广州金域医学检验中心有限公司实验室管理中心吉林金域医学检验所有限公司实验诊断部石家庄金域医学检验所有限公司实验诊断部武汉金域医学检验所有限公司实验诊断部济南金域医学检验中心有限公司实验诊断部

【摘要】 目的建立适合医学检验所检测流程的自动预警程序并运营。方法以实验室信息管理系统(LIS)为基础,建立以预警规则维护、规则漏洞反馈、反馈内容处理、规则效能评估4部分组成的预警程序,在广州医学检验所运营6个月后评估效果。结果成功建立包含13大类规则模板的预警程序,通过异步结构实现6个专业检测流程的多点预警,规则库中包含1 523条规则,平均每天根据规则判断24 000张报告,报告单平均通过率70.2%,单项测试平均通过率83.9%,审核时间较未开启预警减少10~40 min,工作效率提升25%。结论自动预警程序的建立保证了报告质量,缓解了人员压力,提升了工作效率。

【Abstract】 Objective To establish an automatic warning program which accommodates to the test procedures in medical laboratory centerand and to put into operation. Methods Based on laboratory information management system( LIS),automatic warning program was established,which composed of maintenance of warning rules,feedback of vulnerabilities in rules,solutions of feedback targets and evaluation of rule-effectiveness. The results of performance were assessed after operation for six months in Guangzhou Kingmed Medical Laboratory Center. Results An automatic warning program containing 13 kinds of rule templates was successfully established.The multi-point warning program via asynchronous structure for six specialized testing procedures was realized. A total of 1 523 warning rules were included in the rule bank and 24 000 reports were verified on average each day. The average passing rate of reports was70. 2% and the passing rate of single test was 83. 9%. The approval time for reports was reduced by 10 to 40 minutes compared with that without using the automatic warning program. The efficiency for report approval was improved by 25 percent. Conclusion Automatic warning program may ensure the high quality of test reports,ease pressure on staff and improve work efficiency.

  • 【文献出处】 临床检验杂志 ,Chinese Journal of Clinical Laboratory Science , 编辑部邮箱 ,2017年06期
  • 【分类号】R197.6;TP399-C8
  • 【被引频次】8
  • 【下载频次】115
节点文献中: 

本文链接的文献网络图示:

本文的引文网络