节点文献
低温浓缩-气相色谱/质谱法分析固定污染源废气中的丙烯腈
Determination of Acrylonitrile Emissions from Stationary Sources Using Cryogenic Preconcentration Followed by GC/MS
【摘要】 建立了固定污染源废气中丙烯腈的气袋采样-低温浓缩-气相色谱/质谱分析方法。结果表明,该法在丙烯腈质量浓度16.1~4 050μg/m~3范围内具有良好的线性,相关系数R~2>0.999,检出限为9.54μg/m~3,回收率、日内与日间精密度均符合质控要求,能够满足废气中丙烯腈分析的要求。
【Abstract】 This study established a method for the determination of acrylonitrile using cryogenic pre-concentration followed by GC/MS. The results showed that acrylonitrile was in good linearity within 16. 1 ~ 4 050 μg/m~3,and the correlation coefficient was larger than 0. 999. The detection limit was 9. 54 μg/m~3. Meanwhile,the average recovery,the with-in day and inter-day RSDs also met the requirements of quality control. The recoveries of spiked samples were between 86. 9% and 105. 3%,which were stable enough to realize extensive use.
【关键词】 丙烯腈;
气袋;
低温浓缩;
气相色谱/质谱法;
【Key words】 Acrylonitrile; Air bag; Cryogenic pre-concentration; GC/MS;
【Key words】 Acrylonitrile; Air bag; Cryogenic pre-concentration; GC/MS;
- 【文献出处】 环境监控与预警 ,Environmental Monitoring and Forewarning , 编辑部邮箱 ,2017年03期
- 【分类号】X831
- 【被引频次】4
- 【下载频次】35