节点文献

Fluorescent Detection of Cu(Ⅱ) by Chitosan-based AIE Bioconjugate

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 Ya-lan Liu王征科Wei Qin胡巧玲唐本忠

【Author】 Ya-lan Liu;Zheng-ke Wang;Wei Qin;Qiao-ling Hu;Ben Zhong Tang;Ministry of Education Key Laboratory of Macromolecular Synthesis and Functionalization,Department of Polymer Science and Engineering,Zhejiang University;Key Laboratory of Adsorption and Separation Materials & Technologies of Zhejiang Province;Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction,Hong Kong University of Science and Technology;

【机构】 Ministry of Education Key Laboratory of Macromolecular Synthesis and Functionalization,Department of Polymer Science and Engineering,Zhejiang UniversityKey Laboratory of Adsorption and Separation Materials & Technologies of Zhejiang ProvinceDepartment of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction,Hong Kong University of Science and Technology

【摘要】 Detection of Cu(Ⅱ) is very important in disease diagnose, biological system detection and environmental monitoring. Previously, we found that the product TPE-CS prepared by attaching the chromophores of tetraphenylethylene(TPE) to the chitosan(CS) chains showed excellent fluorescent properties. In this study, we tried to use TPE-CS for detecting Cu(Ⅱ) because of the stable complexation of CS with heavy metals and the luminosity mechanism of the Restriction of Intramolecular Rotations(RIR) for aggregation-induced emission(AIE)-active materials. The fluorescence intensity changed when TPE-CS was contacted with different metal ions, to be specific, no change for Na+, slightly increase for Hg2+, Pb2+, Zn2+, Cd2+, Fe2+, Fe3+ due to the RIR caused by the complexation between CS and metal ions. However, for Cu2+, an obvious fluorescence decrease was observed because of the Photoinduced-Electron-Transfer(PET). Moreover, we found that the quenched FL intensity of TPE-CS was proportional to the concentration of Cu(Ⅱ) in the range of 5 μmol/L to 100 μmol/L, which provided a new way to quantitatively detect Cu(Ⅱ) . Besides, TPE-CS has excellent water-solubility as well as absorbability(the percentage of removal, R = 84%), which is an excellent detection probe and remover for Cu(Ⅱ) .

【Abstract】 Detection of Cu(Ⅱ) is very important in disease diagnose, biological system detection and environmental monitoring. Previously, we found that the product TPE-CS prepared by attaching the chromophores of tetraphenylethylene(TPE) to the chitosan(CS) chains showed excellent fluorescent properties. In this study, we tried to use TPE-CS for detecting Cu(Ⅱ) because of the stable complexation of CS with heavy metals and the luminosity mechanism of the Restriction of Intramolecular Rotations(RIR) for aggregation-induced emission(AIE)-active materials. The fluorescence intensity changed when TPE-CS was contacted with different metal ions, to be specific, no change for Na+, slightly increase for Hg2+, Pb2+, Zn2+, Cd2+, Fe2+, Fe3+ due to the RIR caused by the complexation between CS and metal ions. However, for Cu2+, an obvious fluorescence decrease was observed because of the Photoinduced-Electron-Transfer(PET). Moreover, we found that the quenched FL intensity of TPE-CS was proportional to the concentration of Cu(Ⅱ) in the range of 5 μmol/L to 100 μmol/L, which provided a new way to quantitatively detect Cu(Ⅱ) . Besides, TPE-CS has excellent water-solubility as well as absorbability(the percentage of removal, R = 84%), which is an excellent detection probe and remover for Cu(Ⅱ) .

【基金】 financially supported by the Key Science Technology Innovation Team of Zhejiang Province(No.2013TD02);the National Natural Science Foundation of China(Nos.21104067,21274127,21374099 and 51473144)
  • 【文献出处】 Chinese Journal of Polymer Science ,高分子科学(英文版) , 编辑部邮箱 ,2017年03期
  • 【分类号】O636.1;O657.3
  • 【被引频次】12
  • 【下载频次】124
节点文献中: 

本文链接的文献网络图示:

本文的引文网络