从区域性、变工况条件下空调器性能变化和空调器对室内温度分布的影响三个方面对家用空调器性能的研究现状进行了综述和分析,并对分析方法和试验方法进行了改进。分析方法上引入相对制冷量比率(Relative Refrigerating Capacity Percentage,RRCP)、相对制热量比率(Relative Heating Capacity Percentage,RHCP)、相对功率比率(Relative Power Percentage,RPP)和相对能源消耗比率(Relative Energy Consumption Percentage,RECP),分析空调器实测性能与名义性能参数的关系。并提出室外侧温度保持不变,室内侧空调自由运行,室内由初始温度降至空调设定温度的试验方法,此种方法可以对比分析定频空调和变频空调在相同条件下的耗电量和对室内温度分布的影响。
【英文摘要】
This paper analyzed the research status of the performance of household air conditioner from the region,the performance change of air conditioning system under variable working conditions and the effect of air conditioning on indoor temperature distribution,respectively. The analysis method and test method were improved. The relative refrigerating capacity percentage( RRCP),the relative heating capacity percentage( RHCP),the relative power percentage( RPP) and the relative energy efficiency percentage( RECP...