节点文献
Calorimetric power measurements in the EAST ECRH system
【摘要】 In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating(ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature stability is controlled to obtain more accurate results.The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. Also, a novel temperature calibration method is proposed. This kind of calibration method is accurate and effective, and can be easily implemented.
【Abstract】 In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating(ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature stability is controlled to obtain more accurate results.The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. Also, a novel temperature calibration method is proposed. This kind of calibration method is accurate and effective, and can be easily implemented.
【Key words】 power measurement; calorimetric method; data acquisition; EAST tokamak; ECRH;
- 【文献出处】 Plasma Science and Technology ,等离子体科学和技术(英文版) , 编辑部邮箱 ,2017年10期
- 【分类号】TL631.24
- 【被引频次】1
- 【下载频次】20