4℃冷藏保存血小板对体外大失血模型的纠正效果

Corrective effects of 4℃ stored platelets with a hemorrhage modeling in vitro

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 韩宇枫杨江存马婷孙杨尹文谢昕昕王文华宋耀军陈萍胡兴斌张小乐李淑萍

【Author】 HAN Yufeng;YANG Jiangcun;MA Ting;SUN Yang;YIN Wen;XIE Xinxin;WANG Wenhua;SONG Yaogjun;CHEN Ping;HU Xingbin;ZHANG Xiaohe;LI Shuping;Obstetrics and Gynecology Hospital,Shaanxi Provincial People’s Hospita;Department of Transfusion Medicine,Shaanxi Provincial People’s Hospital;Department of Transfusion Medicine,Xijing Hospital,the Fourth Military Medical University;Department of Transfusion Medicinxe,Beijing Tongren Hospital;

【机构】 陕西省人民医院妇产病院陕西省人民医院第四军医大学西京医院北京同仁医院

【摘要】 目的探讨4℃冷藏保存血小板对体外大失血模型的纠正效果。方法手工汇集(10人份)血小板200mL等分为2×100 mL,分别于4℃冷藏保存和22℃振荡保存,共计制备5×200 mL,等分后放置4℃冷藏冰箱和22℃血小板振荡保存箱。采用血液稀释法(全血∶盐水=1∶9)制备体外大失血模型,应用TEG检测指标及血常规等指标对比、评价悬浮红细胞、新鲜冰冻血浆与4℃冷藏保存血小板(简称4℃血小板)或22℃振荡保存血小板(简称22℃血小板)按1∶1∶1比例对体外大失血模型的纠正效果。结果保存1、3、5 d时,4℃血小板组和22℃血小板组在对相同血样制备的体外失血模型纠正,Plt(×109/L)从20-27分别升至127-161 vs 128-160(P>0.05),TEG-MA值(mm)由12.7-14.4分别升至45-51 vs 47-50,TEG-R值(min)由27.7-9.9分别升至4.4-4.3 vs 4.5-4.7(P>0.05)。保存7-14 d,4℃血小板组:Plt(×109/L)由18-27纠正到162-161,TEG-MA值(mm)由8.8-14.5纠正为46-43,TEG-R值(min)由24-13纠正为5.5-5.2(P<0.05)。结论按悬浮红细胞、新鲜冰冻血浆和4℃冷藏保存血小板作用于体外大失血模型达到了纠正效果,佐证了4℃冷藏保存10-14 d的血小板具有良好的止血效果。

【Abstract】 Objective To evaluate the corrective effects of platelets stored at 4℃ with the help of a in vitro hemorrhage model.Platelets agitated at 22℃ were used as comparison.we hope this study would provide valuable experimental bata for the preservation of platelets in clinical applications.Methods Sample platelets with a total volume of 5×200 mL were divided into 2×100 mL each 200 mL for storage at 4℃ and 22℃,respectively.An in vitro model of hemorrhage was established with the in vitro hemodilution method where blood was diluted with normal saline(NS) with a ratio of 1∶9.The in vitro corrective effects of the platelets stored at 4℃ and 22℃ were evalutaed by Thromboelastography(TEG) test and routine blood marker level tests,where these two groups of platelets were prepared in a mix of suspended erythrocytes and fresh frozen plasma with a ratio of 1∶1∶1.Results Platelets stored at 4℃ and those agitated at 22℃ for 1,3,and 5 days were determined to be corrected in the in vitro hemorrhagie model,where platelet counts(×109/L) were corrected from 20-27 to 127-161 and 128-160,respectively(P> 0.05).The TEG-MA(mm) were corrected from 12.7-14.4 to 45-51 and 47-50 while TEG-R values were corrected from 27.7-9.9 to 4.4-4.3 and 4.5-4.7,respectively(P>0.05).For platelets stored at 4℃ for 7-14 days,platelet counts(×10~9/L) were corrected from 18-27 to 162-161 and TEG-MA(mm) were corrected from 8.8-14.5 to 46-43 with TEG-R(min) corrected from 24-13 to 5.5-5.2(P<0..05).Conclusion Correction has been detected using the hemorrhage model.The platelet counts,TEG-R,and TEG-MA values have been corrected,thus supporting the claim that platelets stored at 4℃ for 10-14 days presents fine coagulation quality.

  • 【文献出处】 中国输血杂志 ,Chinese Journal of Blood Transfusion , 编辑部邮箱 ,2017年06期
  • 【分类号】R457.12
  • 【被引频次】4
  • 【下载频次】106