节点文献
AP1000乏燃料池临界安全及影响因素初步研究
Analysis on the Critical Security and Influence Factors of the Spent Fuel Pool
【摘要】 通过对AP1000乏燃料贮存格架进行临界安全分析计算,将贮存格架贮存的乏燃料假设为新燃料,从计算的角度初步验证了该格架能满足临界安全准则,以及将乏燃料贮存池中的水密度作为临界安全的主要影响因素研究乏燃料贮存的临界安全问题.
【Abstract】 In this paper the spent fuel in storage grid is assumed to be the new fuel,then the critical security of AP1000 spent fuel storage rack is analyzed and computed.Preliminary validation shows that the parameters of framework can satisfy the criticality safety standards.And the water density in the spent fuel storage pool will be the main influence factors to study the spent fuel storage criticality safety problems.
【基金】 大型先进压水堆核电站重大专项基金资助项目(2015zx06004002-001)
- 【文献出处】 南华大学学报(自然科学版) ,Journal of University of South China(Science and Technology) , 编辑部邮箱 ,2016年01期
- 【分类号】TM623.8
- 【被引频次】3