Aim at using high voltage discharge in plasma reduction drag,there are some problems on strong electric field interferential general strain gauge signal.Fiber grating sensor may stably work in the strong electric field environment.The balance of fiber grating strain gauge is designed.By adjustment and temperature correction,the precision of balance may satisfy the using demand.In the experiment of plasma reduction drag,the data are identical with the general measurement pressure method.Experimental results ...