节点文献
多b值DWI对术前幕上胶质瘤分级的应用研究
The application study of multi-b value diffusion weighted imaging in preoperative histological grading of supratentorial glioma
【摘要】 目的 探讨何种b值扩散加权成像(DWI)对胶质瘤术前分级更有价值。方法 回顾性分析经手术病理证实的38例胶质瘤(高级别24例、低级别14例)患者的MRI资料,均行常规MRI检查和3种b值的DWI检查(b=1 000 s/mm2、2 000 s/mm2、3 000 s/mm2),分析DWI上肿瘤的信号特征,测量肿瘤最小表观扩散系数(ADC)值。对不同b值的肿瘤最小ADC值绘制受试者工作特征曲线(ROC),选取最佳诊断阈值,采用χ2检验分析不同序列的敏感性、特异性的差异。结果 b=3 000 s/mm2 DWI图像上,91.6%(22/24)高级别胶质瘤呈高信号,85.7%(12/14)低级别胶质瘤呈低信号,以高信号作为诊断高级别胶质瘤的标准,诊断高级别和低级别胶质瘤的敏感性及特异性最高(91.6%和100%)。在b值相同时高级别胶质瘤的最小ADC值低于低级别胶质瘤,差异有统计学意义(P<0.05);3种b值鉴别高级别和低级别胶质瘤敏感性的差异有统计学意义(P<0.05),当以ADC 3 000<0.74×10-3 mm2/s作为鉴别高级别胶质瘤的敏感性和特异性最高,分别为100%和87.3%。结论 高b值DWI比常规b值DWI更能准确反映胶质瘤分级,应用b=3 000 s/mm2 DWI肿瘤最小ADC值为胶质瘤术前更准确分级提供量化指标。
【Abstract】 Objective To investigate the optimal b value of diffusion-weighted imaging(DWI) in predicting the grade of cerebral gliomas.Methods 38 patients with pathologically-proved brain gliomas(24 high-grade gliomas and 14 low-grade ones) were studied retrospectively.All patients received conventional MRI and DWI examination with three different b values(1 000 s/mm2,2 000 s/mm2 and3 000 s/mm2).The signal features of the tumor on DWI with three different b values were evaluated and compared.The minimum ADC values of the tumors were calculated and compared between each other.Through drawing the ROC curve of different b values,the best diagnostic threshold was found.The sensitivity and specificity in predicting the grade of brain gliomas were assessed using Chi-square test.Results On DWI with b value of 3 000 s/mm2,91.6%(22/24) of high-grade tumors showed hyper-intensity,while85.7%(12/14) of low-grade tumors presented hypo-intensity signals.Regarding hyper-intensity signals as diagnostic criterion for high-grade tumors,the sensitivity and specificity were 91.6% and 100% respectively.When the b value was similar,the minimum ADC value of high-grade glioma was significantly lower than that of low-grade glioma,and statistically significant differences in differentiating high-grade glioma from low-grade glioma existed among three b values(P<0.05).When the ADC 3 000 value<0.74×10-3 mm2/s was regarded as a standard for the identification of high-grade and low-grade glioma,the sensitivity and specificity were 100% and 87.3%respectively.Conclusion DWI with high b value is more useful than standard moderate b value in preoperative grading the gliomas.When DWI with b value of 3 000 s/mm2 is used,the minimum ADC value will provide quantitative indicators in preoperatively precisely predicting grading glioma.
- 【文献出处】 实用放射学杂志 ,Journal of Practical Radiology , 编辑部邮箱 ,2016年02期
- 【分类号】R739.41;R445.2
- 【下载频次】3