节点文献
某工程预应力管桩抗拔静载试验破坏原因分析及处理对策
Analysis and Treatments of the Damages of Precast Tubular Piles During Uplifting Static Loading Test in an Engineering Project
【摘要】 针对某工程预应力管桩在抗拔静载试验过程中出现的破坏现象,从现场工程地质条件、试验方法及试验过程等方面深入分析破坏原因,结合现场情况提出相应处理措施后,试桩结果理想,节省了造价,缩短了工期。
【Abstract】 For investigating the reasons of precast tubular pile damage during uplifting static loading test in an engineering project,the geological engineering conditions of experimental field,test methodology and procedure were deeply analyzed. Finally,the main reason for this damage was obtained and the corresponding treatments were also put forward. The results show that the measures are appropriate and the cost and construction period are saved.
【关键词】 预应力;
预应力混凝土;
管桩;
抗拔桩;
静载试验;
承载力;
【Key words】 prestressing; prestressed concrete; piles; anti-lifting piles; static loading test; bearing capacity;
【Key words】 prestressing; prestressed concrete; piles; anti-lifting piles; static loading test; bearing capacity;
- 【文献出处】 施工技术 ,Construction Technology , 编辑部邮箱 ,2016年09期
- 【分类号】TU473.1
- 【被引频次】2
- 【下载频次】108