节点文献
特高压输电线路工频参数测试干扰水平的计算与测量
Interference Level Calculation and Measurement of UHV Transmission Line Frequency Parameters Test
【摘要】 分析输电线路工频参数测试干扰产生的机理,应用电磁暂态仿真软件EMTP对廊坊—泉城特高压输电线路工频参数测试的干扰水平进行计算,并通过实测数据验证仿真计算方法的正确性。为特高压输电线路工频参数测试方案制定提供理论指导,保障该线路工频参数测试人员及设备的安全,避免陪停邻近线路带来的经济损失。
【Abstract】 The mechanism of power line parameter test interference of transmission line is analyzed, and through the electrical transient analyzer program( EMAP), the interference level of the power-frequency parameter measurement of Langfang-Quancheng UHV transmission line is calculated. The calculation method is proved to be accurate by practical measurements.Calculation results can provide a theoretical guidance for power-frequency parameters measurement scheme and guarantee the safety of personnel and equipment. At the same time, the economic loss caused by adjacent transmission line power failure is avoided.
【Key words】 UHV; transmission line; power-frequency parameters measurement; interference level;
- 【文献出处】 山东电力技术 ,Shandong Electric Power , 编辑部邮箱 ,2016年12期
- 【分类号】TM75
- 【被引频次】2
- 【下载频次】34