Taking a ground powerhouse structure for hydropower station for an example,the structure of the numerical model was established by using large finite element software to check the influence of project and the size. The reason for this is because the upper structure is in low stiffness relatively. First this paper conducted the calculation and analysis of the upper structure under the static and dynamic load,comparing all kinds of case calculation results,thus stiffness and strength characteristic were analy...