节点文献
超高压液相色谱-轨道阱质谱法测定加工食品中30种禁用工业染料
Determination of 30 Forbidden Industrial Dyes in Processed Food by UHPLC-Orbitrap Mass Spectrometry
【摘要】 采用超高压液相色谱-四极杆静电场轨道阱质谱法测定食品中30种禁用工业染料。样品用乙腈-丙酮-氨水(66+33+1)混合液提取,所得提取液经Oasis HLB和中性氧化铝串联固相萃取柱净化后进行色谱分离,用Thermo Gold C18柱作固定相,并以不同体积比的乙腈和0.1%(φ)甲酸溶液的混合液作流动相进行梯度淋洗。质谱分析中,采用电喷雾正离子源和选择离子扫描-数据依赖的二级采集模式(Target SIM-dd MS2)检测。所得30种染料的检出限在0.001 0~0.051mg·kg-1之间。加标回收率在85.2%~96.5%之间,相对标准偏差(n=6)在2.1%~9.8%之间,质量的相对偏差在±5×10-6以内。
【Abstract】 UHPLC-electrostatic quadrupole/orbitrap mass spectrometry was applied to the determination of30 forbidden industrial dyes in processed food.The sample was extracted with acetonitrile-acetone-aqueous ammonia(66+33+1)mixture,and the extract obtained was purified on HLB and neutral alumina solid-phase extraction column.The purified extract was separated by HPLC using Thermo Gold C18 column as stationary phase,and mixtures of acetonitrile and 0.1%(φ)formic acid solution in various ratios as mobile phase in gradient elution.Electrospray ionization positive ion source and the mode of Target Selected Ion Monitoring-Data Dependent MS2 scanning(Target SIM-dd MS2)were adopted in the mass spectrometry.Detection limits for the 30 forbidden industrial dyes were in the range of 0.001 0-0.051mg·kg-1.Recovery was tested by standard addition method,giving results in the range of 85.2%-96.5%,with RSDs(n=6)ranged from 2.1% to 9.8%.The mass relative deviation was within ±5×10-6.
【Key words】 UHPLC; Orbitrap mass spectrometry; Forbidden industrial dye; Processed food;
- 【文献出处】 理化检验(化学分册) ,Physical Testing and Chemical Analysis(Part B:Chemical Analysis) , 编辑部邮箱 ,2016年09期
- 【分类号】O657.63;TS207.5
- 【被引频次】4