节点文献

Measurement of photoelectron yield of the CDEX-10 liquid argon detector prototype

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈庆豪岳骞程建平康克军李元景林兴德唐昌建幸浩洋余训臻曾鸣朱敬军

【Author】 Qing-Hao Chen;Qian Yue;Jian-Ping Cheng;Ke-Jun Kang;Yuan-Jing Li;Shin-Ted Lin;Chang-Jian Tang;Hao-Yang Xing;Xun-Zhen Yu;Ming Zeng;Jing-Jun Zhu;Department of Engineering Physics,Tsinghua University;Key Laboratory of Particle and Radiation Imaging,Tsinghua University,Ministry of Education;College of Physical Science and Technology,Sichuan University;

【机构】 Department of Engineering Physics,Tsinghua UniversityKey Laboratory of Particle and Radiation Imaging,Tsinghua University,Ministry of EducationCollege of Physical Science and Technology,Sichuan University

【摘要】 The China Dark Matter Experiment(GDEX) is a low background experiment at China Jinping Underground Laboratory(CJPL) designed to directly detect dark matter with a high-purity germanium(HPGe) detector.In the second phase,CDEX-10,which has a 10 kg germanium array detector system,a liquid argon(LAr) antiCompton active shielding and cooling system is proposed.To study the properties of the LAr detector,a prototype with an active volume of 7 liters of liquid argon was built and operated.The photoelectron yields,as a critically important parameter for the prototype detector,have been measured to be 0.051-0.079 p.e./keV for 662 keV γ rays at different positions.The good agreement between the experimental and simulation results has provided a reasonable understanding and determination of the important parameters such as the surviving fraction of the Ar2* excimers,the absorption length for 128 nm photons in liquid argon,the reflectivity of Teflon and so on.

【Abstract】 The China Dark Matter Experiment(GDEX) is a low background experiment at China Jinping Underground Laboratory(CJPL) designed to directly detect dark matter with a high-purity germanium(HPGe) detector.In the second phase,CDEX-10,which has a 10 kg germanium array detector system,a liquid argon(LAr) antiCompton active shielding and cooling system is proposed.To study the properties of the LAr detector,a prototype with an active volume of 7 liters of liquid argon was built and operated.The photoelectron yields,as a critically important parameter for the prototype detector,have been measured to be 0.051-0.079 p.e./keV for 662 keV γ rays at different positions.The good agreement between the experimental and simulation results has provided a reasonable understanding and determination of the important parameters such as the surviving fraction of the Ar2* excimers,the absorption length for 128 nm photons in liquid argon,the reflectivity of Teflon and so on.

  • 【文献出处】 Chinese Physics C ,中国物理C , 编辑部邮箱 ,2016年11期
  • 【分类号】P145.9
  • 【下载频次】36
节点文献中: 

本文链接的文献网络图示:

本文的引文网络