The uniform similitude law was applied to design the model of high-rise buildings beyond the codespecification in shaking table test in consideration of transfinite height,multiple layers,overall complexity and other characteristics of the structure. Three kinds of weight models were used in design calculation to discuss the rationality,namely,the model with artificial masses,the model neglecting gravity forces and the model without enough artificial masses. The results showed that out of these three models...