Based on the centrifugal machine system,a test apparatus was set up to investigate the operating characteristics of dual compensation chambers loop heat pipe( DCCLHP) under both gravity and acceleration fields. The ranges of the heat load and the magnitude of acceleration are 25- 300 W and 3g- 9g,respectively. The influences of different heat loads,acceleration directions and magnitudes on temperature fluctuations of loop heat pipe were analyzed. The results indicate that the effect of the acceleration can ...
【基金】
中央高校基本科研业务费专项资金(YWF-14-HKXY-019)~~
【更新日期】
2016-08-15
【分类号】
V444.3
【正文快照】
网络出版地址:www.cnki.net/kcms/detail/11.2625.V.20151119.1006.003.html引用格式:薛好,谢永奇,戴华,等.加速度场中环路热管温度波动现象分析[J].北京航空航天大学学报,2016,42(7):1502-1508.XUE H,XIE Y Q,DAI H,et al.Investigation of temperature fluctuation in loop h