节点文献

羟甲基纤维素钠(CMC)溶液中同轴复合搅拌桨的功率特性和混合特性研究(英文)

Power demand and mixing performance of coaxial mixers in a stirred tank with CMC solution

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 包雨云陆语梁千顷李力高正明黄雄斌秦松

【Author】 Yuyun Bao;Yu Lu;Qianqin Liang;Li Li;Zhengming Gao;Xiongbin Huang;Song Qin;State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology;Lanzhou Petrochemical,Petro China;

【机构】 State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical TechnologyLanzhou Petrochemical,Petro China

【摘要】 Experimental investigation was carried out in an elliptical based stirred tank with a diameter of 0.48 m to explore the power demand and mixing performance of coaxial mixers.Syrup and CMC solution(sodium carboxy methyl cellulose)were used as the Newtonian and non-Newtonian fluids,respectively.Four different coaxial mixers were combined with either CBY or Pfaudler impeller as the inner one,and anchor or helical ribbon(HR)as the outer one.Results show that Pfaudler-HR is the optimized combination among four coaxial mixers in this work,which provides the shortest mixing time given the same power consumption.Compared with the syrup solution,the increase of power input can make the mixing time decreasing more obviously in the CMC solution.The quantitative correlations for both syrup and CMC solutions were established to calculate the power draw and the mixing time of four coaxial mixers.

【Abstract】 Experimental investigation was carried out in an elliptical based stirred tank with a diameter of 0.48 m to explore the power demand and mixing performance of coaxial mixers.Syrup and CMC solution(sodium carboxy methyl cellulose)were used as the Newtonian and non-Newtonian fluids,respectively.Four different coaxial mixers were combined with either CBY or Pfaudler impeller as the inner one,and anchor or helical ribbon(HR)as the outer one.Results show that Pfaudler-HR is the optimized combination among four coaxial mixers in this work,which provides the shortest mixing time given the same power consumption.Compared with the syrup solution,the increase of power input can make the mixing time decreasing more obviously in the CMC solution.The quantitative correlations for both syrup and CMC solutions were established to calculate the power draw and the mixing time of four coaxial mixers.

  • 【文献出处】 Chinese Journal of Chemical Engineering ,中国化学工程学报(英文版) , 编辑部邮箱 ,2015年04期
  • 【分类号】TQ051.71
  • 【被引频次】13
  • 【下载频次】221
节点文献中: 

本文链接的文献网络图示:

本文的引文网络