节点文献

基于全自动管式化学发光免疫检测系统的人结核感染T细胞检测方法的建立

Development of detection kit for T cell infected with Mycobacterium tuberculosis based on fullautomatic chemiluminescence immune analyzer

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈鹭颖林海军翁祖星徐飞海葛胜祥张军

【Author】 CHEN Luying;LIN Haijun;WENG Zuxing;XU Feihai;GE Shengxiang;ZHANG Jun;Fujian Food and Drug Administration;National Institute of Diagnostics and Vaccine Development in Infectious Diseases,Xiamen University;

【机构】 福建省食品药品认证审评中心厦门大学国家传染病诊断试剂与疫苗工程技术研究中心

【摘要】 目的建立基于化学发光平台的人结核感染T细胞检测方法。方法将一株γ-干扰素单抗标记在磁微粒上,另一株γ-干扰素单抗标记在吖啶酯上,然后将检测体系与已有的细胞刺激培养体系相结合。结果本研究成功建立基于化学发光平台的人结核感染T细胞检测方法。以ELISA平台检测试剂的检测结果作为参考,该方法的灵敏度为98.3%,特异性为99.2%,总体符合率达到98.8%。结论该方法具有更高的分析灵敏度(可达0.27 pg/m L)、更宽的线性范围(1 pg/m L~5 000 pg/m L)、更好的重复性(批内与批间变异系数均<6.0%)及更易实现高通量检测,为临床诊断结核感染提供了有力的工具。

【Abstract】 Objective To develop the detection kit for T cell infected with Mycobacterium tuberculosis based on full-automatic chemiluminescence immune analyzer. Mehtods An anti IFN-γ Mab was coated on the surface of microparticle. Another anti IFN-γ Mab was labelled to acridinium ester. After that, the detection system was combined with the in vitro cell culture system. Results This research developed the detection kit for T cell infected with Mycobacterium tuberculosis based on full-automatic chemiluminescence immune analyzer. Compared with the testing results of the ELISA kit, the sensitivity, specificity and total matching ratio of the CLIA kit was 98.3%, 99.2% and 98.8%, respectively. Conclusion The CLIA kit has better sensitivity(0.27 pg/m L), wilder linear range(1 pg/m L ~ 5 000 pg/m L), and better repeatability(intra and inter coefficient of variation < 6.0%). It makes a high throughput detection available. It will contribute to the clinical diagnosis of Mycobacterium tuberculosis.

【基金】 国家高技术研究发展计划(863计划)(2011AA02A101)
  • 【文献出处】 分子诊断与治疗杂志 ,Journal of Molecular Diagnostics and Therapy , 编辑部邮箱 ,2015年05期
  • 【分类号】R446.6
  • 【被引频次】4
  • 【下载频次】187