低频力学谱仪低温致冷装置的改进设计

An Improved Design of Cryogenic Cooling Device with Low Frequency Mechanical Spectroscopy

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨洪张永康刘聃扬

【Author】 YANG Hong;ZHANG Yong-kang;LIU Dan-yang;School of Mechano-electrical Engineering,Suzhou Vocational University;

【机构】 苏州市职业大学机电工程学院

【摘要】 针对目前材料低温力学谱测试实验中采用手动方式推送液氮致冷,温度控制受人为因素影响较大,存在温度控制精度不高、控制过程时间较长等缺点,提出一种低温致冷装置的改进设计方案.低温致冷装置通过温控仪和温度传感器自动控制试样温度,使得实验环境温度快速稳定在实验目标温度,实现温控过程的自动化,控制精度较高.同时,低温致冷装置还具有较强的推广与应用价值.

【Abstract】 The supply of liquid nitrogen in the low temperature mechanical spectroscopy experiment is handworked.It causes some problems,such as influences from the operators,low precision of temperature and long stability controling time. Thus an improved cryogenic cooling device is designed.It controls the sample’s temperature with temperature controller and temperature sensor.The cryogenic cooling device makes the temperature stable quickly.It realizes temperature control automatically with high precision.Also,it provides a reference for other experiments which need cryogenic cooling devices.

【基金】 江苏省“青蓝工程”资助项目;江苏省“333工程”资助项目;苏州市职业大学研究性课程资助项目(SZDYKC-150503)
  • 【文献出处】 苏州市职业大学学报 ,Journal of Suzhou Vocational University , 编辑部邮箱 ,2015年04期
  • 【分类号】TH87
  • 【被引频次】1
  • 【下载频次】55