尾气湿含量对气液交叉流阵列捕集PM2.5的影响
Effect of Exhaust Humidity Ratio on PM2.5 Collection by Gas-liquid Cross-flow
【摘要】 针对过程工业尾气中PM2.5治理难题,提出以废水-废气构建的气液交叉流降膜阵列系统,利用工业尾气冷凝组分冷凝捕集尾气中PM2.5。基于质量衡算和传质速率方程,得到以尾气湿含量为控制参数的气液交叉流PM2.5捕集效率模型。理论结果表明,进口尾气湿含量从0.28kg/kg增加到0.52kg/kg,单排降膜阵列PM2.5捕集效率从0.64%增加到1.26%。湿含量为0.52kg/kg时,预测182排降膜阵列组成长度为819mm的分离通道整体分离效率可达到90%。通过20列×90排降膜阵列进行实验验证,表明理论与实验结果基本一致。
【Abstract】 According to PM2.5pollution problem of industrial exhaust,agas-liquid cross-flow falling film array system using exhaust-wastewater was proposed.PM2.5was collected by humid exhaust condensation.On the basis of mass balance and the rate equation of mass transfer,a PM2.5collection efficiency model with exhaust humidity ratio as key parameter was got,theoretical results showed that with the import humidity ratio increased from 0.28kg/kg to 0.52kg/kg,single row of falling film array could achieve PM2.5collection efficiency from 0.64% to 1.26%.819 mm separation channel consisting of 182 rows of liquid columns could get 90% collection efficiency when humidity ratio was 0.52kg/kg.Experiments using cross-flow falling film array consisting of 20 row ×90line were done,theoretical and experimental results had the same trend.
【Key words】 PM2.5; gas-liquid cross-flow; falling film array; humidity ratio; collection efficiency;
- 【文献出处】 四川化工 ,Sichuan Chemical Industry , 编辑部邮箱 ,2015年03期
- 【分类号】X701
- 【被引频次】3
- 【下载频次】51