节点文献

A user-friendly nano-CT image alignment and 3D reconstruction platform based on Lab VIEW

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王圣浩张凯王志立高昆吴朝朱佩平吴自玉

【Author】 WANG Sheng-Hao;ZHANG Kai;WANG Zhi-Li;GAO Kun;WU Zhao;ZHU Pei-Ping;WU Zi-Yu;National Synchrotron Radiation Laboratory,University of Science and Technology of China;Institute of High Energy Physics,Chinese Academy of Sciences;

【机构】 National Synchrotron Radiation Laboratory,University of Science and Technology of ChinaInstitute of High Energy Physics,Chinese Academy of Sciences

【摘要】 X-ray computed tomography at the nanometer scale(nano-CT) offers a wide range of applications in scientific and industrial areas. Here we describe a reliable,user-friendly,and fast software package based on Lab VIEW that may allow us to perform all procedures after the acquisition of raw projection images in order to obtain the inner structure of the investigated sample. A suitable image alignment process to address misalignment problems among image series due to mechanical manufacturing errors,thermal expansion,and other external factors has been considered,together with a novel fast parallel beam 3D reconstruction procedure that was developed ad hoc to perform the tomographic reconstruction. We have obtained remarkably improved reconstruction results at the Beijing Synchrotron Radiation Facility after the image calibration,the fundamental role of this image alignment procedure was confirmed,which minimizes the unwanted blurs and additional streaking artifacts that are always present in reconstructed slices. Moreover,this nano-CT image alignment and its associated 3D reconstruction procedure are fully based on Lab VIEW routines,significantly reducing the data post-processing cycle,thus making the activity of the users faster and easier during experimental runs.

【Abstract】 X-ray computed tomography at the nanometer scale(nano-CT) offers a wide range of applications in scientific and industrial areas. Here we describe a reliable,user-friendly,and fast software package based on Lab VIEW that may allow us to perform all procedures after the acquisition of raw projection images in order to obtain the inner structure of the investigated sample. A suitable image alignment process to address misalignment problems among image series due to mechanical manufacturing errors,thermal expansion,and other external factors has been considered,together with a novel fast parallel beam 3D reconstruction procedure that was developed ad hoc to perform the tomographic reconstruction. We have obtained remarkably improved reconstruction results at the Beijing Synchrotron Radiation Facility after the image calibration,the fundamental role of this image alignment procedure was confirmed,which minimizes the unwanted blurs and additional streaking artifacts that are always present in reconstructed slices. Moreover,this nano-CT image alignment and its associated 3D reconstruction procedure are fully based on Lab VIEW routines,significantly reducing the data post-processing cycle,thus making the activity of the users faster and easier during experimental runs.

【关键词】 nano-CTimage alignment3D reconstructionLab VIEW
【Key words】 nano-CTimage alignment3D reconstructionLab VIEW
【基金】 Supported by Major State Basic Research Development Program(2012CB825800);Science Fund for Creative Research Groups(11321503);Knowledge Innovation Program of The Chinese Academy of Sciences(KJCX2-YW-N42);National Natural Science Foundation of China(11179004,10979055,11205189,11205157);Fundamental Research Funds for the Central Universities(WK2310000021)
  • 【文献出处】 Chinese Physics C ,中国物理C , 编辑部邮箱 ,2015年01期
  • 【分类号】O434.1;TP391.41
  • 【被引频次】4
  • 【下载频次】89
节点文献中: 

本文链接的文献网络图示:

本文的引文网络