【作者】 杨国民涂乐义程存峰张向阳胡水明

【Author】 Guo-min Yang;Le-yi Tu;Cun-feng Cheng;Xiang-yang Zhang;Shui-ming Hu;Hefei National Laboratory for Physical Sciences at the Microscale,University of Science and Technology of China;Institute of Hydrogeology and Environmental Geology,Chinese Academy of Geological Sciences;

【机构】 中国科学技术大学合肥微尺度物质国家实验室中国地质科学院水文地质环境地质研究所

【摘要】 原子阱痕量分析是一种基于激光的新方法,能够对数微升氪气中丰度低至10-1485Kr和81Kr原子进行计数测量.介绍了在合肥建成的痕量放射性氪同位素测量系统,包括ATTA装置、水中溶解气提取和氪气分离提纯的样品处理设备.利用该系统对国内多处大气中85Kr浓度的测量结果为1.31.6 Bq/m3,与文献中北半球大气本底值相吻合.对华南和华北的几个浅层和深层地下水样品进行了85Kr和81Kr测年,示范了该系统的应用.

【Abstract】 Because of their unique chemical and physical properties,long-lived rare krypton radioisotopes,85Kr and 81Kr,are ideal tracers for environmental samples,including air,groundwater and ice.Atom trap trace analysis(ATTA) is a new laser-based method for counting both85Kr and 81Kr atoms with the abundance as low as 10-14 with micro-liters(STP) krypton gas.The entire system for rare radio-krypton measurement built at Hefei is presented,including the atom trap trace analysis instrument and sampling apparatus of gas extraction from water and krypton purification.Atmospheric 85Kr concentrations at different places in China were measured,showing a range of 1.3-1.6 Bq/m3,consistent with the northern hemispheric baseline.As a demonstration of the system,some shallow and deep groundwater samples in north and south China were sampled and dated.

【关键词】 原子阱痕量分析85Kr81Kr地下水测年
【Key words】 Atom trap trace analysis85Kr81KrGroundwaterDating
【基金】 supported by the National Natural Science Foundation of China(No.21225314,No.41102151);Special Fund for Land and Resources Research in the Public Interest(No.201511046);supported by INQUA-IFG1309F,IGCP-618and Guangdong Bureau of Water Conservation(2014-2016)
  • 【文献出处】 Chinese Journal of Chemical Physics ,化学物理学报(英文版) , 编辑部邮箱 ,2015年04期
  • 【分类号】O613.14;TN249