节点文献

Benzotriazole removal on post-Cu CMP cleaning

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 唐继英刘玉岭孙鸣樊世燕李炎

【Author】 Tang Jiying;Liu Yuling;Sun Ming;Fan Shiyan;and Li Yan;Institute of Microelectronics, Hebei University of Technology;Electrical Engineering Department, Tianjin Metallurgical Vocation-Technology Institute;

【机构】 Institute of Microelectronics Hebei University of TechnologyElectrical Engineering Department Tianjin Metallurgical Vocation-Technology Institute

【摘要】 This work investigates systematically the effect of FA/O II chelating agent and FA/O I surfactant in alkaline cleaning solutions on benzotriazole(BTA) removal during post-Cu CMP cleaning in GLSI under the condition of static etching. The best detergent formulation for BTA removal can be determined by optimization of the experiments of single factor and compound cleaning solution, which has been further confirmed experimentally by contact angle(CA) measurements. The resulting solution with the best formulation has been measured for the actual production line, and the results demonstrate that the obtained cleaning solution can effectively and efficiently remove BTA, Cu O and abrasive Si O2 without basically causing interfacial corrosion. This work demonstrates the possibility of developing a simple, low-cost and environmentally-friendly cleaning solution to effectively solve the issues of BTA removal on post-Cu CMP cleaning in a multi-layered copper wafer.

【Abstract】 This work investigates systematically the effect of FA/O II chelating agent and FA/O I surfactant in alkaline cleaning solutions on benzotriazole(BTA) removal during post-Cu CMP cleaning in GLSI under the condition of static etching. The best detergent formulation for BTA removal can be determined by optimization of the experiments of single factor and compound cleaning solution, which has been further confirmed experimentally by contact angle(CA) measurements. The resulting solution with the best formulation has been measured for the actual production line, and the results demonstrate that the obtained cleaning solution can effectively and efficiently remove BTA, Cu O and abrasive Si O2 without basically causing interfacial corrosion. This work demonstrates the possibility of developing a simple, low-cost and environmentally-friendly cleaning solution to effectively solve the issues of BTA removal on post-Cu CMP cleaning in a multi-layered copper wafer.

【基金】 Project supported by the Major National Science and Technology Special Projects(No.2009ZX02308)
  • 【文献出处】 Journal of Semiconductors ,半导体学报(英文版) , 编辑部邮箱 ,2015年06期
  • 【分类号】TN305
  • 【被引频次】5
  • 【下载频次】39
节点文献中: 

本文链接的文献网络图示:

本文的引文网络