节点文献

A rapid method for determination of acid value in transformer oil by PPy modified electrode

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 熊英何德良冯勇周舟常新园刘芙蓉

【Author】 XIONG Ying;HE De-liang;FENG Yong;ZHOU Zhou;CHANG Xin-yuan;LIU Fu-rong;College of Chemistry and Chemical Engineering,Hunan University;Hunan Electric Power Corporation Research Institute;

【机构】 College of Chemistry and Chemical Engineering,Hunan UniversityHunan Electric Power Corporation Research Institute

【摘要】 A polypyrrole-modified glassy carbon electrode(PPy/GC electrode)was prepared and its electrocatalytic behavior towards naphthoquinone in the presence of acid was characterized by linear sweep voltammetry(LSV).A well-defined new reduction peak appeared at a more positive potential than the original reduction peak.The new reduction peak current was linearly related to the acid value(AV)of oil.Based on it,a rapid electrochemical method for determining AV of transformer oil was developed using PPy/GC electrode.A working curve was obtained in the AV range of 0.01 to 0.40 mg(KOH)·g-1,with a sensitivity of 39.42 μA0.5/(mg(KOH)·g-1)and the detection limit of 0.0014 mg(KOH)·g-1(signal-to-noise ratio is 3,standard deviation is 2.247%).Moreover,the proposed method has been successfully applied to AV determination of several transformer oil samples with advantages of rapidness,high sensitivity and accuracy compared to the conventional method.

【Abstract】 A polypyrrole-modified glassy carbon electrode(PPy/GC electrode)was prepared and its electrocatalytic behavior towards naphthoquinone in the presence of acid was characterized by linear sweep voltammetry(LSV).A well-defined new reduction peak appeared at a more positive potential than the original reduction peak.The new reduction peak current was linearly related to the acid value(AV)of oil.Based on it,a rapid electrochemical method for determining AV of transformer oil was developed using PPy/GC electrode.A working curve was obtained in the AV range of 0.01 to 0.40 mg(KOH)·g-1,with a sensitivity of 39.42 μA0.5/(mg(KOH)·g-1)and the detection limit of 0.0014 mg(KOH)·g-1(signal-to-noise ratio is 3,standard deviation is 2.247%).Moreover,the proposed method has been successfully applied to AV determination of several transformer oil samples with advantages of rapidness,high sensitivity and accuracy compared to the conventional method.

【基金】 Project(11JJ3015)supported by the Natural Science Foundation of Hunan Province,China
  • 【文献出处】 Journal of Central South University ,中南大学学报(英文版) , 编辑部邮箱 ,2014年06期
  • 【分类号】TE626.3;O646
  • 【下载频次】27
节点文献中: 

本文链接的文献网络图示:

本文的引文网络