节点文献
输液连接件(肝素帽)可沥滤物检测浸提条件的确定
The Determination of the Extraction Conditions on the Inspection of the Leachable Substances of the Infusion Access Adapters (Heparin Plugs)
【摘要】 通过各种标准中浸提比例的比较和实际产品表面积的测量,确定浸提比例为1克样品加20ml蒸馏水。在不同浸提条件下,对产品化学性能(还原物质、酸碱度、重金属、紫外吸光度)测定结果进行了比较,确定最佳浸提条件为37±1?C,24h。
【Abstract】 Through the comparison of some standards on extraction ratio and measurements of the surface of products, the extraction ratio was determined, which was 1 gram of sample with 20 ml of distilled water. The chemical requirements, such as reducing matters, pH, metal ions and UV absorbance, were tested under different extraction conditions. The best extraction conditions were determined as 37±1?C and 24 h.
【关键词】 输液连接件;
肝素帽;
可沥滤物;
浸提比例;
浸提条件;
化学性能;
【Key words】 infusion access adapter; heparin plug; leachable substance; extraction ratio; extraction condition; chemical requirements;
【Key words】 infusion access adapter; heparin plug; leachable substance; extraction ratio; extraction condition; chemical requirements;
- 【文献出处】 中国医疗器械信息 ,China Medical Device Information , 编辑部邮箱 ,2014年04期
- 【分类号】R197.39
- 【被引频次】1
- 【下载频次】161