节点文献
电催化氧化降解含酚工业废水实验研究
An Experimental Study of Electro-catalytic Oxidation of Phenol-Containing Industrial Wastewater
【摘要】 采用价廉的涤纶滤膜作为电解体系隔膜,利用阴、阳极同时作用降解含酚工业废水,在反应时间80min,曝气量1.2L/min,电流密度30mA/cm2的最佳条件下,含酚废水COD去除率可达到80%,阴极室COD去除率高于阳极室。
【Abstract】 This paper studies electro-catalytic oxidation of phenol wastewater using inexpensive polyester membrane as a electrolytic diaphragm system with anode and cathode functioning simultaneously.The optimum conditions of wastewater treatment are determined as follows:the current density is 30mA/cm2,aeration rate is 1.2L/min,electrolysis time is 80min.Under these conditions,the removal rates of COD could reach 80%.
【关键词】 电催化氧化;
阴阳极同时氧化;
含酚废水;
【Key words】 electro-catalytic oxidation; simultaneous oxidation of anode and cathode; phenol-containing wastewater;
【Key words】 electro-catalytic oxidation; simultaneous oxidation of anode and cathode; phenol-containing wastewater;
- 【文献出处】 唐山学院学报 ,Journal of Tangshan College , 编辑部邮箱 ,2014年03期
- 【分类号】X703.1;X78
- 【被引频次】4