节点文献
MBR工艺深度处理印刷电路板废水的研究
Study on Advanced Treatment of Printed Circuit Board Wastewater By MBR Process
【摘要】 分别采用陶瓷膜和超滤膜生物反应器对某印刷电路板(PCB)厂现有废水处理厂出水进行深度处理研究。结果表明:在进水COD 191.2?270.4 mg/L,氨氮30?50 mg/L,MLSS 6 500 mg/L,DO 4?8 mg/L,反应时间为5 h的条件下,两种膜生物反应器出水COD和氨氮的浓度分别低于99.2 mg/L和0.759 mg/L,达到《污水综合排放标准》(GB8978-1996)中的一级排放标准。
【Abstract】 The ceramic and hollow fiber ultrafiltration membrane bioreactors were separately applied for advanced treatment of the printed circuit board(PCB) wastewater.The results show that,when concentration of dissolved oxygen(DO) is 4.0~8.0 mg/L,hydrodynamic retention time(HRT) is 5 h,MLSS is 6500 mg/L,COD and ammonia nitrogen are 191.2~270.4 mg/L and 30.0~50.0 mg/L respectively,COD and ammonia nitrogen in the effluent from membrane bioreactors are less 99.2 mg/L and 0.759 mg/L respectively;The quality of treated wastewater can meet the first grade of Integrated Wastewater Discharge Standard GB8978-1996.
【Key words】 Printed circuit board wastewater; Membrane bioreactor; Ceramic membrane; Hollow fiber ultrafiltration membrane;
- 【文献出处】 当代化工 ,Contemporary Chemical Industry , 编辑部邮箱 ,2014年03期
- 【分类号】X703.1;X76
- 【被引频次】5
- 【下载频次】187