气相色谱质谱法(GC/MS)检测饲料中的20种塑化剂残留

Determination of 20 pthalates in feed by Gas Chromatography-Mass Spectrometry

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 周红霞华春唐慧敏

【Author】 ZHOU Hong-xia;HUA Chun;TANG Hui-min;School of Biochemical and Environmental Engineering of Nanjing Xiaozhuang University;Jiangsu Agro-product Quality Test Center;

【机构】 南京晓庄学院生物化工与环境工程学院江苏省农产品质量检验测试中心

【摘要】 建立气相色谱-质谱(GC/MS)法测定和确证饲料中塑化剂的残留量。试样用正己烷提取,气相色谱分离、质谱选择离子方式(SIM)对20种邻苯二甲酸酯进行定性,内标法定量分析。该方法操作简单、准确可靠、重现性良好,各种邻苯二甲酸酯化合物的方法检出限为10.2~701μg/kg,加标回收率为80%~109%,相对标准偏差为1.0%~5.9%,能够满足饲料中邻苯二甲酸酯类化合物含量的测定。

【Abstract】 An analytical method to determine 20 phthalates in feed was presented using liquid-liquid extraction and gas chromatography-mass spectrometry(GC-MS). The sample pretreatment before GC-MS analysis was achieved by liquid-liquid extraction with n-hexane. The presented method was simple,accurate,reliable and reproducible. The limits of detection of this method for 18 phthalates tested were in the range of 10.2~701μg/kg. The average spike recovery rates of these phthalates from blank feed samples varied from 80% ~109% with relative standard deviation of 1.0% ~5.9%. This method could meet the requirements for the determination of phthalates in feed.

【基金】 国家高技术发展研究计划(“863”计划)(2012AA021701)
  • 【文献出处】 食品工业科技 ,Science and Technology of Food Industry , 编辑部邮箱 ,2014年10期
  • 【分类号】S816.17
  • 【被引频次】5
  • 【下载频次】237