节点文献
Current leads for superconducting magnets of ADS injector Ⅰ
【摘要】 In an ADS injector, there are five superconducting magnets in each cryomodule. Each superconducting magnet contains a solenoid magnet, a horizontal dipole corrector(HDC), and a vertical dipole corrector(VDC). Six current leads will be required to power the electrical circuits, from room temperature to the 2.1 K liquid helium bath: two leads carry 100 A current for the solenoid magnet while the other four carry 12 A for the HDC and the VDC. This paper presents the principle of current lead optimization, which includes the cooling methods, the choice of material and structure, and the issues for current lead integration.
【Abstract】 In an ADS injector, there are five superconducting magnets in each cryomodule. Each superconducting magnet contains a solenoid magnet, a horizontal dipole corrector(HDC), and a vertical dipole corrector(VDC). Six current leads will be required to power the electrical circuits, from room temperature to the 2.1 K liquid helium bath: two leads carry 100 A current for the solenoid magnet while the other four carry 12 A for the HDC and the VDC. This paper presents the principle of current lead optimization, which includes the cooling methods, the choice of material and structure, and the issues for current lead integration.
【Key words】 current lead; heat load; superconducting magnet;
- 【文献出处】 Chinese Physics C ,中国物理C , 编辑部邮箱 ,2014年06期
- 【分类号】O482.54
- 【被引频次】3
- 【下载频次】42