节点文献

Experimental studies of THGEM in different Ar/CO2 mixtures

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 何占营周健荣孙志嘉杨桂安许虹王艳凤刘倩刘宏邦陈石谢一冈郑阳恒王晓冬张小东胡碧涛陈元柏

【Author】 HE Zhan-Ying;ZHOU Jian-Rong;SUN Zhi-Jia;YANG Gui-An;XU Hong;WANG Yan-Feng;LIU Qian;LIU Hong-Bang;CHEN Shi;XIE Yi-Gang;ZHENG Yang-Heng;WANG Xiao-Dong;ZHANG Xiao-Dong;HU Bi-Tao;CHEN Yuan-Bo;School of Nuclear Science and Technology,Lanzhou University;Institute of High Energy Physics Chinese Academy of Sciences;State Key Laboratory of Particle Detection and Electronics;University of Chinese Academy of Sciences;

【机构】 School of Nuclear Science and Technology,Lanzhou UniversityInstitute of High Energy Physics Chinese Academy of SciencesState Key Laboratory of Particle Detection and ElectronicsUniversity of Chinese Academy of Sciences

【摘要】 In this paper,the performance of a type of domestic THGEM(THick Gaseous Electron Multiplier)working in Ar/CO2 mixtures is reported in detail.This kind of single THGEM can provide a gain range from 100to 1000,which is very suitable for application in neutron detection.In order to study its basic characteristics as a reference for the development of a THGEM based neutron detector,the counting rate plateau,the energy resolution and the gain of the THGEM have been measured in different Ar/CO2 mixtures with a variety of electrical fields.For the Ar/CO2(90%/10%) gas mixture,a wide counting rate plateau is achieved from 720 V to 770 V,with a plateau slope of 2.4%/100 V,and an excellent energy resolution of about 22%is obtained at the 5.9 keV full energy peak of the 55Fe X-ray source.

【Abstract】 In this paper,the performance of a type of domestic THGEM(THick Gaseous Electron Multiplier)working in Ar/CO2 mixtures is reported in detail.This kind of single THGEM can provide a gain range from 100to 1000,which is very suitable for application in neutron detection.In order to study its basic characteristics as a reference for the development of a THGEM based neutron detector,the counting rate plateau,the energy resolution and the gain of the THGEM have been measured in different Ar/CO2 mixtures with a variety of electrical fields.For the Ar/CO2(90%/10%) gas mixture,a wide counting rate plateau is achieved from 720 V to 770 V,with a plateau slope of 2.4%/100 V,and an excellent energy resolution of about 22%is obtained at the 5.9 keV full energy peak of the 55Fe X-ray source.

【基金】 Supported by National Natural Science Foundation of China(11127508,11175199);NPL,CAEP(Project 2013DB06)
  • 【文献出处】 Chinese Physics C ,中国物理C , 编辑部邮箱 ,2014年05期
  • 【分类号】O571.53
  • 【被引频次】6
  • 【下载频次】64
节点文献中: 

本文链接的文献网络图示:

本文的引文网络